Where to rent
Black Mojo Barriers in an indoor arena

Certification

Crowd barrier
certification

Our crowd barrier certification rests on 16 documents from four independent testing bodies, TNO, Lloyd's British Testing, TÜV Nederland and TÜV NORD Nederland, dated 1996 to 2025.

Independent testing

Developed by us,
tested by others

Mojo Barriers BV develops its barrier systems and has had them independently tested since 1996. Certification is carried out by independent bodies such as TÜV NORD.

A test result applies only to the specimen that was tested. The 2025 TÜV NORD certificate states this in its own words: “only for the tested test specimens”. If you are new to the system, start with what a Mojo Barrier® is or browse the barrier range.

Aerial view of a Mojo Barrier corner in front of a stage

Test history

Tested since 1996

Five tests, listed newest first, each with its document number, basis and result. The same approach to evidence runs through our crowd safety research.

2025TÜV NORD

TÜV NORD Nederland B.V.

Certificate TÜV-NL-2410-D-228 · 16 June 2025

The current black range was certified.

5 kN/mrequired load, met by all four products
2028valid until 16 June 2028
Basis
Section 7.5 of Temporary Demountable Structures, Fourth Edition, Institution of Structural Engineers
Products
  • Mojo G3 Straight
  • Mojo G3 Vario
  • Mojo G3 Flex
  • Mojo G3 Cablegate

View the four certificates

2013TÜV NL

TÜV Nederland Q.A. B.V.

Certificates 2013-A-168-C0 and 2013-A-168-C1 · 12 December 2013

Member of TÜV NORD Group. Two aluminium barrier ranges were certified after one test programme.

5 kN/mtest load, no non-conformities
2certificates, one per range
Basis
Strength, overturning resistance, sliding behaviour
2013-A-168-C0
MOJO G2 Barrier Alu: Straight, Flex corner, Vario corner
2013-A-168-C1
MOJO G1 Barrier Alu: Straight, Vario and Flex corners, Snake Runner and Snake Gate, 22.5° and 45° corners (positive and negative)

View the two certificates

2011Lloyd's

Lloyd's British Testing Ltd

Certificate 03.06.11 SB 01 · tested 2 June 2011

Eight corner, gate and wedge modules were each tested on their own as a sample at the Lloyd's British works in London.

5 kN/mrequired by BS EN 13200-3:2005
8 of 8passed, no permanent deformation
Tested load per module. The white line marks the required 5 kN/m, the scale runs from 0 to 8 kN/m.
Flex Corner5.3 kN/m
Vario Corner5 kN/m
Snake Gate5.50 kN/m
5.5° Positive Fixed Corner Section Wedge7.66 kN/m
22.5° Positive Fixed Corner Section5.08 kN/m
22.5° Negative Fixed Corner Section5.08 kN/m
45° Positive Fixed Corner Section7.46 kN/m
45° Negative Fixed Corner Section5.56 kN/m

View the eight certificates

1998TNO

TNO Building and Construction Research

Test report 98-CON-R0777 · 12 April 1998

The aluminium barrier was tested as a prototype in the year it was developed.

5.1 kN/mhorizontal on the top rail, no permanent deformation
Basis
Strength test
Sliding
Not significantly different from the earlier steel barrier

View the test report

1996TNO

TNO Building and Construction Research

Test report 96-CON-R0748 · 11 May 1996

Three steel barriers made in 1990 and 1992 were loaded as single units in the TNO laboratory in April 1993 to find out how they fail: by bending, overturning or sliding.

6.6 kN/mstrength (ultimate limit state) at the upper rail
5.3 kN/moverturning starts, load applied 1.1 m above the ground
Basis
Strength, overturning resistance, sliding behaviour
Failure
Bending of the lower frame

View the test report

For product details, see the Straight Section and the Cable Gate, or browse all stage barriers.

Documents

View the certificates

Each sheet below is an image of the original document, large enough to read. The TÜV NORD certificate lists MOJO Rental in Germany under “Marketed by, under the brand name”. MOJO Rental is a rental company of the MOJO Holding Group, the group to which Mojo Barriers BV also belongs.

TÜV NORD Nederland · 4
TÜV Nederland · 2
Lloyd's British Testing · 8
TNO · 2
TÜV NORD certificate TÜV-NL-2410-D-228, Mojo G3 Straight, 2025
TÜV NORD certificate TÜV-NL-2410-D-228, Mojo G3 Vario, 2025
TÜV NORD certificate TÜV-NL-2410-D-228, Mojo G3 Flex, 2025
TÜV NORD certificate TÜV-NL-2410-D-228, Mojo G3 Cablegate, 2025
TÜV Nederland certificate 2013-A-168-C0, MOJO G2 Barrier Alu, 2013
TÜV Nederland certificate 2013-A-168-C1, MOJO G1 Barrier Alu, 2013
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 1, Flex Corner, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 2, Vario Corner, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 4, Snake Gate, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 5, 5.5° positive corner wedge, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 6, Fixed Corner 22.5°, positive, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 7, Fixed Corner 22.5°, negative, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 8, Fixed Corner 45°, positive, 2011
Lloyd's British Testing certificate 03.06.11 SB 01, sheet 9, Fixed Corner 45°, negative, 2011
TNO test report 98-CON-R0777, aluminium prototype Mojo Barrier, 1998, cover page
TNO test report 96-CON-R0748, steel Mojo Barrier, 1996, cover page
Certificate 01 / 16Mojo G3 StraightTÜV NORD Nederland B.V.
Certificate 02 / 16Mojo G3 VarioTÜV NORD Nederland B.V.
Certificate 03 / 16Mojo G3 FlexTÜV NORD Nederland B.V.
Certificate 04 / 16Mojo G3 CablegateTÜV NORD Nederland B.V.
Certificate 05 / 16MOJO G2 Barrier AluTÜV Nederland Q.A. B.V.
Certificate 06 / 16MOJO G1 Barrier AluTÜV Nederland Q.A. B.V.
Certificate 07 / 16Flex CornerLloyd's British Testing Ltd
Certificate 08 / 16Vario CornerLloyd's British Testing Ltd
Certificate 09 / 16Snake GateLloyd's British Testing Ltd
Certificate 10 / 165.5° Positive Fixed Corner WedgeLloyd's British Testing Ltd
Certificate 11 / 1622.5° Positive Fixed CornerLloyd's British Testing Ltd
Certificate 12 / 1622.5° Negative Fixed CornerLloyd's British Testing Ltd
Certificate 13 / 1645° Positive Fixed CornerLloyd's British Testing Ltd
Certificate 14 / 1645° Negative Fixed CornerLloyd's British Testing Ltd
Test report 15 / 16Aluminium prototype, 1998TNO Building and Construction Research
Test report 16 / 16Steel barrier, 1996TNO Building and Construction Research

FAQ

Questions about
certification

For product data in a tender or a site plan, you can specify a barrier system step by step. How testing fits into the wider picture is part of our health and safety approach.

Yes. In report 96-CON-R0748, TNO measured the sliding resistance of a single steel barrier unit on three surfaces:

SurfaceSliding resistance
Smooth concrete floor with finishing2.9 kN (2.6 kN/m)
Carpet4.1 kN (3.7 kN/m)
Rubber mat4.3 kN (3.9 kN/m)

Besides the module, the required and tested load and the result (“no permanent set recorded on unit”, pass), each sheet gives:

  • the model number, for example Flex Corner B100100
  • the sample size, for example 1000 mm by 1200 mm
  • the proof load applied, given in kgf
  • until 16 June 2028 at the latest
  • as long as the product specifications, methods, production instructions and conditions of use do not change significantly
  • as long as the certificate has not been suspended or revoked
  • its current validity can be checked with TÜV NORD Nederland via tuv.nl

BS EN 13200-3:2005 is the standard Lloyd's British Testing used in 2011 for eight Mojo Barrier modules, each against a required 5 kN/m. Its full title is “Spectator facilities – Part 3: Separating elements – Requirements”. The 2005 edition has since been replaced, so the sheets describe what was tested in 2011 and nothing about later editions.

No. The certificates are shown as images in the document viewer on this page, not as downloads. The data sheets and brochure are available separately. For anything else about a document, contact Mojo Barriers BV.

Fans at the Mojo front-of-stage barrier at night

Rent

Tested barriers, available to rent

Mojo Barriers are rented through the rental companies of the MOJO Holding Group, such as MOJO Rental. The Where to rent page lists them.